Adding one course of block to a slab keeps the garage door framing farther up from the ground which may be necessary depending on the grade.
Thickened slab at garage door opening.
After digging down 2 of pure sand i decided to stop compact it and fill the hole with gravel.
150 to 250 mm 1 for longer spans drop panels thickened portions of the slab are added at the columns this system is referred to as a flat slab and has an economical span range of 25 to 30 ft 7 5 to 9 m with minimum slab thicknesses of 8 5 to 10 in.
For a 5 in thick slab with thickened edges which is perfect for most garages and sheds 2x12 boards work best.
The wall should be stepped down at the the door 8 10 below the top of the slab.
The cost of concrete for a slab garage floor includes the delivery of concrete and any material overages as a result of waste.
Mum slab thicknesses of 6 to 10 in.
Type 1 is sometimes referred to as a thickened slab garage foundation and type 2 is often referred to as a stem wall garage foundation and type 3 is often referred to as a hybrid stem wall garage foundation for the reason that it is a combination of both type 1 and type 2 and is often used in areas that have highly plastic soils conditions such.
2x12 cleat over the joint.
200 to 250 mm two way beam.
The second sheet is for a similar situation however in this case i am considering option 2 where the stem wall has been blocked out and a thickened edge slab spans the gap created by the garage door.
If your slab is heated it s a good idea to increase the r value of the vertical and the horizontal insulation to at least r 20.
Monolithic or thickened edge slabs can only be insulated on the exterior.
I plan on reinforcing the slab with 15m bars on 12 centers both ways and put two around the slab perimeter and one inside the perimeter wall.
Pouring just a slab with a thickened perimeter is the least expensive and a perfectly acceptable option if you have good soil conditions not spongy.
In climate zones 4 and 5 building codes require a minimum of r 10 vertical insulation that extends down 2 ft.
Start by choosing straight form boards.
There will be a 16 x 8 garage door for.
The wall should have a key and 5 bars at 12 16 o c.
For a driveway or other slab without thickened edges use 2x6s.
You want the slab to move with the building not the driveway.
I am treating the footing and the thickened edge as a single grade beam similar to as shown in this typical detail.
As per the present market rates the average cost of concrete for a 400 square foot slab the typical size for a two car garage.
The slab should have a thickened edge at the wall with a couple of 5 s running the lenght of the opening.
I will be building 10 high walls with 2x6 then put on the roof.